Rheem heater Water is not hot


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402
Water is not hot



If your water heater has NO hot water, then click circuit breaker

Next, click red reset button.
Turn off power.
Open cover on water heater.
If heater has 2 covers, open top cover
After re-seting water heater, insulation must be put back over thermostat to prevent cooler air from affecting thermostat.

1) Reset button is a good starting place to check water heater.
Reset clicks off for a number of reasons, including overheated water.

2) Reset will not reset, then replace thermostat.
http://waterheatertimer.org/How-to-replace-thermostat-on-electric-water-heater.html

3) Resets clicks on, but clicks off again later, you should diagnose the problem.
Clicking reset is not a hazard 
Click the reset as often as you want until you have time to diagnose.
http://waterheatertimer.org/How-to-troubleshoot-electric-water-heater.html

4) Reset is not tripped, and you still do not have hot water:
Then use tester on top two screws (T1 - T3 screws -or- 1 and 3 screws) of upper thermostat to check if you have power.

If you have power, then replace thermostat. 
If problems continue, a full diagnosis is needed as per the link above

If you need more help, add a comment and I will respond

Water heater pressure is very low


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402


MY HOTWATER PRESSURE IS VERY LOW WHICH IS MAKING MY HOTWTER COME OUT VERY SLOW ALL OVER THE HOUSE. THE COLD WATER RUNS AT A VERY HIGH CONSTANT SPEED. SO HOW DO I FIGURE OUT WHY THE PRESSURE FOR THE HOTWTER IS SO SLOW.

Close the valve that on top of the water heater on the col side on due the hot side house, and screw in a 3/4gage valve on top of heater then open the valve the one you close and you will read the pressure on the gauge ; you'll know if is your tank is clog you could have at least 50 psi on you're gauge.

My job is to give you resources that can help you for free.

http://www.thetankatwaterheaterrescue.com/forums/forum3/
The link above goes to professional plumbers.
They will know and see more things than I can short-list for you.
They will probably tell you to take apart the lines going into water heater to see if problem is before or after water heater. Or if the problem is inside the water heater.
The problem might be at the shut off valve located on cold water line going into heater.
If you have hard water, the problem could be at an elbow.



Water heater Humming

NOISY WATER HEATER


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402

Started humming periodically when using hot water and tankis filling up with cold water

Usually when a tank is making noise, it means the tank needs to be cleaned out or flushed.
I wrote a page with diagrams showing how to clean out a tank, and how to flush the tank.
Page shows gas and electric water heaters.
See if this helps:
http://waterheatertimer.org/Clean-sediment-out-of-water-heater.html

RHEEM 81V400 water Heater element


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402

Which element do i need for a RHEEM 81V400 water heater?

Rheem bolt-in element is 4500 watt.
Buy at hardware store or plumbing supply.


rheem water heater Not enough hot water,running out


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402


Not enough hot water,running out before I'm finished showering.



Hello,

Hot water heaters are a touchy thing. There performance depends on your demand. If you are using an energy saving shower head I would expect you to have enough hot water for easily a couple of showers. But, if your using the "power flush" type shower heads that use 3.5 gpm or more, the 40 gallon heater is not enough. Also, consider type of water your heating. Is it well water or municipal. Unsoftened well (this includes some municipal well supplies too) water causes hardness ions to cake the heater element making them less efficient. If you have the low flow shower, it is likely you have an element burnt out. They can simply be replaced and picked up at any big box store for less than $20 dollars. Each element can be tested in place with a continuity tester. If your not sure how to test, but would be willing to replace the elements - replace both of them. You will have to shut off power to heater and drain tank completely before removing elements. Replace elements with same wattage or higher. Most have two 2250 watt elements for a total of 4500 watts. you can easily install two 3000 watt elements and have a quicker recovery rate and more hot water than ever.

=======
If it is a 40 gallon tank,. and has the potential to produce plenty of hot water. then drain out the hot water tank! it may have a lot of scale build up in it. a water heater has to be drained at least every year or so. but that depends on the quality of the water going to it. they say its a good practice to drain out a few gallons every 6 months, to ensure it is clean. but i have a 40 gallon tank, and it has been in for about 5 years. no problems. but the water going in is real good. just hook a hose to bottom drain, and run out a few gallons till it appears clean or all sludge is out.

===========

Rheem water heater will not turn on at all


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402


Rheem 83xr52-2 50 gal residential water heater. Water temp was low. I cut power at electric panel, removed upper panel on water heater, turned up thermostat, replaced panel and switched power back on at electric panel. Now water heater won't turn on at all. 


Solution:---
You can open the top up again. I would not turn the temp higher than 130 degrees, maximum. However, there should be above the thermostat a red button. This is where the power wires connect to the thermostats and heating elements. Sometimes this button needs to be reset, press it and discern if you hear a click sound. This means that the high temperature safety switch has tripped open and you had to manually "reset" it. There are two thermostats by the way. The water heater usually works this way. There are two thermostats and two heaters. The upper tank heater turns on first and it heats the top half of the tank. Then when the thermostat above is satisfied it then allows the bottom heater to come on and heat the bottom half of the tank. You might want to set the bottom heater thermostat as well. This is made this way because it is actually faster and more efficient to heat the top half first and the bottom half secondly. Try this first with the reset button. We could check voltages, but that requires a level of knowledge and safety that I am not sure that you are comfortable with. Pictures of the upper and lower thermostats and connections will help if the "reset" does not do the trick. By the way, not meaning or implying anything, but did you move the thermostat in the right direction? Sometimes the dials can be confusing.

More Details:---

Electric water heater is completely repairable by homeowner.

What to do right now:
Check circuit breaker
Push in red reset button on upper thermostat and see if that restores some hot water.
Put insulation and cover back so thermostat does not receive cooler air and misread tank temperature which can cause overheated tank that causes reset button to trip.
Turn thermostat back to where it was.
That way you have some hot water until problem is fixed tomorrow.

Break down problem:
You were short of hot water.
That says electricity to water heater is good and upper element is working.
And it says original problem is one of 4 things.

1) Loose wire going to lower part of water heater. Check parts for signs of heat damage at screw terminals, especially lower element. 
Burned lower element means lower element probably bad.
http://waterheatertimer.org/Replace-element-and-clean-sediment-out-of-electric-water-heater.html

2) Bad upper thermostat ***** This is best suspect since water heater stopped completely after temperature adjustment.
3) Bad lower thermostat. I usually replace both thermostats at same time.
http://waterheatertimer.org/How-to-replace-thermostat-on-electric-water-heater.html

4) Bad lower element. Test element using inexpensive multimeter from Home Depot electric department.
http://waterheatertimer.org/How-to-test-water-heater-element.html

Here are repair steps:
Buy generic upper and lower thermostat and replace both thermostats, and if problem persists, then replace lower element.

If you want to test water heater parts before replacing anything:
http://waterheatertimer.org/How-to-troubleshoot-electric-problems-with-water-heater.html

Upper thermostats are interchangeable
Upper thermostat for 2-element tank has 3 screws on right side of thermostat


Air in water heater lines


Problem with Rheem 40 GAL ELEC TALL Water Heater 6YR SC 82VH402


I suddenly got air in my hot water lines. Not all the time but has happened three or four times. At the same time it seems as though I have less hot water than I used to. Is it an element or do you think that it is a fill line issue? 40 gal Rheem electric in a mobile home 1996



Sorry to read about your problem, I hope this helps you out.

sounds like you have a defective fill tube, plus you water heater is on the old side, and is getting past the fail point....